Bosch Praesideo peripheral components
Click to view more information about each component.
- Praesideo PLN-24CH12 24 V and PRS-48CH12 48
V Battery Chargers
- Praesideo PRS-NSP Network
Splitter
- Praesideo PRS-FIN, PRS-FINNA and PRS-FINS Fiber
Interfaces
- Praesideo LBB 4442/00 Line Supervision Set
- Praesideo LBB 4440/00 Supervision Control Board
- Praesideo LBB 4441/00 Loudspeaker Supervision
Board
- Praesideo LBB 4443/00 End of Line (EOL) Supervision
Board
- Praesideo LBB 4416/xx Network Cables
For
more information about Bosch Praesideo voice evacuation systems
please do not hesitate to contact
us directly. Or
if you know which part you are looking for, please complete
our quotation request
form and our Bosch team will respond to your enquiry immediately.
|
|
|
|
Praesideo PLN-24CH12
24 V and PRS-48CH12 48 V Battery Chargers |
|
Features: |
|
- 12 A battery charger
- 6x 40 A, 3x 5 A outputs
- 150 A back-up current
- Fully supervised, EN 54-4 certified
- Under-voltage and over-voltage protection
The PLN-24CH12 and PRS-48CH12 Battery Chargers are
designed for public address and emergency sound systems,
to assure that the system batteries are always charged.
Rack mountable, the unit charges lead-acid batteries
and simultaneously provides 24 V or 48 V for system
components that use 24 V or 48 V exclusively. These
chargers are fully compliant and certified to EN 54-4.
For more information download the Databook below...
|
10 |
|
|
|
|
Praesideo PRS-NSP
Network Splitter |
|
|
Features: |
|
Two current-limited network tap-offs
Supports redundant network connection on main
loop
Can feed power from an external supply to the
network
Indicators for power and fault status
The network splitter is used in a network to
provide two branches from the main cable run.
It can use an external DC power supply, or it
can use the power supply from the network controller.
The unit automatically switches to the local power
supply unit when it is connected to it, reducing
the power drain on the main network. For more
information download the Datasheet below....
|
|
|
|
|
|
|
|
Praesideo PRS-FIN,
PRS-FINNA and PRS-FINS Fiber Interfaces |
|
|
Features: |
|
- Redundant network connection
- Indicators for power and fault status
- Two supervised control inputs (not PRS-FINNA)
- Can use a local power supply
Most of the Praesideo system units have plastic fiber
optic interfaces. Plastic fiber is used to interconnect
nodes which are less than 50 meters apart. For distances
of more than 50 meters, glass fiber optic cable is used.
A fiber interface converts from plastic to glass fiber,
and vice versa. For more information download the Datasheet
below...
|
|
|
|
|
|
|
Praesideo LBB 4442/00
Line Supervision Set |
|
|
Features: |
|
- Loudspeaker line monitoring without additional cabling
- Supervision-master mounting in the power amplifier
- Supervision-slave mounting at the end of the loudspeaker
line
- Open-circuit fault detection
- Compatible with 100 V and 70 V loudspeaker lines
The Praesideo system uses a unique loudspeaker line
monitoring principle, which requires no additional cable.
The loudspeaker line itself is used to communicate with
the supervision-slave installed at the end of the loudspeaker
line. For more information download the Datasheet below...
|
|
|
|
|
|
|
Praesideo LBB 4440/00
Supervision Control Board |
|
|
Features: |
|
- Multiple speaker and line monitoring without additional
cabling
- Mounted inside the power amplifier
- Controls up to 80 speaker and line supervision boards
- Open-circuit fault detection
- Compatible with 100 V and 70 V loudspeaker lines
The board controls the communication between the Praesideo
system and the loudspeaker or loudspeaker line supervision
boards. The LBB 4440/00 is the supervision control board,
monitoring multiple supervision-slave boards (LBB 4441/00
and LBB 4443/00), which are mounted inside the loudspeakers
on the line. For more information download the Datasheet
below...
|
|
|
|
|
|
|
Praesideo LBB 4441/00
Loudspeaker Supervision Board |
|
|
Features: |
|
- Loudspeaker and loudspeaker line monitoring without
additional cabling
- Open-circuit fault detection
- Compatible with 100 V and 70 V loudspeaker lines
- Powering of the supervision-board from the power amplifier
- Communication is not affected by the audio signals
on the loudspeaker line
The board monitors the integrity of a loudspeaker.
It works together with the LBB 4440/00 Supervision Control
Board. The speaker status is communicated to the LBB
4440/00 via the existing loudspeaker cable. For more
information download the Datasheet below...
|
|
|
|
|
|
|
Praesideo LBB 4443/00
End of Line (EOL) Supervision Board |
|
|
Features: |
|
- Loudspeaker line monitoring without additional cabling
- Open-circuit fault detection
- Compatible with 100 V and 70 V loudspeaker lines
- Powering of the supervision-board from the power amplifier
- Communication is not affected by the audio signals
on the line
The board monitors the integrity of a loudspeaker line.
The boards work together with the LBB 4440/00 Supervision
Control Board to monitor the status of the loudspeaker
line and all of its branches. The line status is communicated
to the LBB 4440/00 via the existing loudspeaker cable.
For more information download the Datasheet below...
|
|
|
|
|
|
|
Praesideo LBB 4416/xx
Network Cables |
|
Features: |
|
The network cables come in different lengths with
connectors at both ends. The extension of the type number
indicates the length of the cable. The LBB 4416/00 comes
without connectors. The connectors (LBB 4417/00) are
available for it separately.
For more information download the Datasheet below...
|
|
|
|
|
|
|